| CIRCUIT BREAKER 3VT3 STANDARD SWITCHING CAPACITY ICU=36KA, 415V AC 3-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH OHNE HILFS/ALARMSCHALTER |
|
Technical data: | | |
Width | mm | 210 |
Height | mm | 275 |
Depth | mm | 117 |
Product function / ground-fault protection | | No |
Continuous current / rated value | A | 630 |
Operating voltage / for main current circuit | | |
- at 50 Hz / for AC / maximum
| V | 690 |
- at 60 Hz / for AC / maximum
| V | 690 |
| V | 440 |
Impulse voltage resistance / rated value | kV | 8 |
Number of poles | | 3 |
Active power loss / maximum | W | 75 |
Operating cycles / maximum | 1/h | 120 |
Operating frequency | | |
| Hz | 50 |
| Hz | 60 |
Breaking capacity limit short-circuit current (lcu) | | |
| kA | 60 |
| kA | 36 |
| kA | 20 |
| kA | 15 |
Breaking capacity operating short-circuit current (lcs) | | |
| kA | 40 |
| kA | 18 |
| kA | 10 |
| kA | 8 |
Pouvoir d'enclenchement courant de court-circuit (Icm) / ? 415 V / valeur assign?e | kA | 75 |
Type of mounting | | fixed mounting |
Design of the electrical connection / for main current circuit | | screw-type terminals |
Arrangement of electrical connectors / for main current circuit | | front side |
Number of NC contacts / for auxiliary contacts | | 0 |
Number of NO contacts / for auxiliary contacts | | 0 |
Number of change-over switches / for auxiliary contacts | | 0 |
Product component | | |
- undervoltage release mechanism
| | No |
| | No |
- undervoltage release with leading contact
| | No |
Compatibilit? d'utilisation / sectionneur | | Yes |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | Q |
- according to DIN EN 61346-2
| | Q |
Ambient temperature | | |
| | |
| °C | -40 |
| °C | 70 |
| | |
| °C | -40 |
| °C | 70 |
Derating temperature / for the rated value of the continuous current | °C | 55 |
Protection class IP | | IP40 |
Product function | | |
| | Yes |
- for zero conductors / short-circuit and overload protection
| | No |
Built in orientation | | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back |
Mechanical operating cycles as operating time / typical | | 20,000 |
Electrical operating cycles as operating time / typical | | 5,000 |
|
Certificates/approvals: |
|
|
Further information: |
Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/lowvoltage/catalogs |
Industry Mall (Online-Bestellsystem) http://www.siemens.com/lowvoltage/mall |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3VT3763-2AA36-0AA0/all |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VT3763-2AA36-0AA0 |
CAx-Online-Generator http://www.siemens.com/cax |
|
|
|
last change: | Feb 6, 2012 |