| SIPLUS ET200S 4DI (1PU=5PCS) -25...+60 DGR C WITH CONFORMAL COATING BASED ON 6ES7131-4BD01-0AA0 . ELECTRONIC MODULE 24V DC WIDTH: 15 MM 5 PCS PER PACKAGING UNIT |
|
Supply voltage |
24 V DC | Yes; From power module |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Input current |
from backplane bus 3.3 V DC, max. | 10 mA |
from supply voltage L+, max. | Dependent on encoder |
Encoder supply |
Output voltage | min. L+ (-0.5 V), under load |
Output current, rated value | 500 mA |
Output current, permissible range | 0 to 500 mA |
Power losses |
Power loss, typ. | 0.7 W |
Address area |
Address space per module |
with packing | 4 bit |
without packing | 1 byte |
Digital inputs |
Number/binary inputs | 4 |
Input characteristic curve acc. to IEC 61131, Type 1 | Yes |
Input voltage |
Type of input voltage | DC |
Rated value, DC | 24 V |
for signal "0" | -30 to +5 V |
for signal "1" | 15 to 30 V |
Input current |
for signal "1", typ. | 7 mA; at 24 V |
Input delay (for rated value of input voltage) |
for standard inputs |
Parameterizable | No |
at "0" to "1", min. | 2 ms; typically 3 ms |
at "0" to "1", max. | 4.5 ms |
at "1" to "0", min. | 2 ms; typically 3 ms |
at "1" to "0", max. | 4.5 ms |
Cable length |
Cable length, shielded, max. | 1000 m |
Cable length unshielded, max. | 600 m |
Encoder |
Connectable encoders |
2-wire sensor | Yes |
Permissible quiescent current (2-wire sensor), max. | 1.5 mA |
Interrupts/diagnostics/status information |
Diagnostic messages |
Diagnostic functions | No |
Diagnostics indication LED |
Group error SF (red) | No |
Status indicator digital input (green) | Yes; per channel |
Galvanic isolation |
Galvanic isolation digital inputs |
between the channels | No |
between the channels and the backplane bus | Yes |
Permissible potential difference |
between different circuits | 75 VDC / 60 VAC |
Isolation |
Isolation checked with | 500 V DC |
Ambient conditions |
Extended ambient conditions |
Relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity |
with condensation / maximum | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) |
Resistance |
to biologically active substances / conformity with EN 60721-3-3 | Yes; , Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
to chemically active substances / conformity with EN 60721-3-3 | Yes; , Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! |
to mechanically active substances / conformity with EN 60721-3-3 | Yes; , Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Mechanical and climatic conditions during operation |
Climatic conditions in operation |
Temperature |
Min. | -25 °C; = Tmin |
max. | 60 °C; = Tmax |
Standards, approvals, certificates |
CE mark | Yes |
Dimensions |
Width | 15 mm |
Height | 81 mm |
Depth | 52 mm |
Weight |
Weight, approx. | 35 g |
Status | Mar 12, 2012 |