| SIPLUS S7-1200 SM1234 4AI/2AO FOR MEDIAL STRESS WITH CONFORMAL COATING BASED ON 6ES7234-4HE30-0XB0 . ANALOG I/O +/-10V: 14 BIT RESOLUTION OR 0-20 MA: 13 BIT RESOLUTION |
|
Supply voltage |
24 V DC | Yes |
Input current |
Current consumption, typ. | 60 mA |
from backplane bus 5 V DC, typ. | 80 mA |
Power losses |
Power loss, typ. | 2 W |
Analog inputs |
Number of analog inputs | 4; Current or voltage differential inputs |
permissible input frequency for current input (destruction limit), max. | ± 35 V |
permissible input voltage for voltage input (destruction limit), max. | 35 V |
permissible input current for voltage input (destruction limit), max. | 40 mA |
Cycle time (all channels) max. | 625 µs |
permissible input current for current input (destruction limit), max. | 40 mA |
Input ranges |
Voltage | Yes; ±10 V, ±5 V, ±2.5 V |
Current | Yes; 0 to 20 mA |
Thermocouple | No |
Resistance thermometer | No |
Resistance | No |
Input ranges (rated values), voltages |
-10 V to +10 V | Yes |
Input resistance (-10 V to +10 V) | ≥9 MOhm |
-2.5 V to +2.5 V | Yes |
Input resistance (-2.5 V to +2.5 V) | ≥9 MOhm |
-5 V to +5 V | Yes |
Input resistance (-5 V to +5 V) | ≥9 MOhm |
Input ranges (rated values), currents |
0 to 20 mA | Yes |
Input resistance (0 to 20 mA) | 280 Ω |
Thermocouple (TC) |
Temperature compensation |
Parameterizable | No |
Analog outputs |
Number of analog outputs | 2; Current or voltage |
Output ranges, voltage |
-10 to +10 V | Yes |
Output ranges, current |
0 to 20 mA | Yes |
Load impedance (in rated range of output) |
with voltage outputs, min. | 1000 Ω |
with current outputs, max. | 600 Ω |
Analog value creation |
Measurement principle | Differential |
Integrations and conversion time/ resolution per channel |
Resolution (incl. overrange) | Voltage: 14 bits; Current : 13 bits |
Resolution with overrange (bit including sign), max. | 12 bit; + sign |
Integration time, parameterizable | Yes |
Interference voltage suppression for interference frequency f1 in Hz | 40 dB, DC to 60 V for interference frequency 50 / 60 Hz |
Smoothing of measured values |
Parameterizable | Yes |
Step: None | Yes |
Step: low | Yes |
Step: Medium | Yes |
Step: High | Yes |
Errors/accuracies |
Temperature error (relative to input area) | 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range |
Temperature error (relative to output area) | 25 °C ±0.3% to 55 °C ±0.6% total measurement range |
Basic error limit (operational limit at 25 °C) |
Voltage, relative to input area | +/- 0,1 % |
Current, relative to input area | +/- 0,1 % |
Voltage, relative to output area | +/- 0,3 % |
Current, relative to output area | +/- 0,3 % |
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency |
common mode voltage, max. | 12 V |
Interrupts/diagnostics/status information |
Alarms |
Alarms | Yes |
Diagnostic alarm | Yes |
Diagnostic messages |
Diagnostic functions | Yes |
Monitoring the supply voltage | Yes |
Wire break | Yes |
Short circuit | Yes |
Diagnostics indication LED |
for status of the inputs | Yes |
For status of the outputs | Yes |
for maintenance | Yes |
Galvanic isolation |
Galvanic isolation analog outputs |
between the channels and the power supply of the electronics | No |
Ambient conditions |
Extended ambient conditions |
Relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity |
with condensation / maximum | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) |
Resistance |
to biologically active substances / conformity with EN 60721-3-3 | Yes; , Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
to chemically active substances / conformity with EN 60721-3-3 | Yes; , Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
to mechanically active substances / conformity with EN 60721-3-3 | Yes; , Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Climatic and mechanical conditions for storage and transport |
Climatic conditions for storage and transport |
Free fall |
Drop height, max. (in packaging) | 0.3 m; five times, in dispatch package |
Temperature |
Permissible temperature range | -40 °C to +70 °C |
Mechanical and climatic conditions during operation |
Climatic conditions in operation |
Temperature |
Min. | 0 °C; = Tmin |
max. | 55 °C; = Tmax |
Degree and class of protection |
IP20 | Yes |
Standards, approvals, certificates |
CE mark | Yes |
FM approval | Yes |
Connection method |
required front connector | Yes |
Mechanics/material |
Type of housing (front) | |
Plastic | Yes |
Dimensions |
Width | 45 mm |
Height | 100 mm |
Depth | 75 mm |
Weight |
Weight, approx. | 220 g |
Status | Mar 12, 2012 |