3VL9
Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
3VL9280-8TC00
|
ÏÐÈÍÀÄËÅÆÍÎÑÒÜ ÄËß VL160 ÒÐÀÍÑÔÎÐÌÀÒÎÐ ÒÎÊÀ ÄËß ÇÀÙÈÒÛ ÎÒ ÏÅÐÅÃÐÓÇÊÈ Â N-ÏÐÎÂÎÄÍÈÊÅ È ÊÇ ÍÀ ÇÅÌËÞ IN=63A/80A
|
SIEMENS
|
3VL9230-4TD31
|
ÀÊÑÅÑÑÓÀÐ ÄËß VL150UL, (DG-FRAME) ROUND CONDUCTOR TERMINAL ÄËß CU/AL COMPRISING 3 TERMINALS 3-ÏÎËÞÑÀ ONLY ÄËß 60 - 150 A
|
SIEMENS
|
3VL9220-4TN31
|
ÀÊÑÅÑÑÓÀÐ ÄËß VL160 BOX TERMINALS COMPRISES 3 BOX TERMINALS AND TERMINAL COVER 3-ÏÎË.
|
SIEMENS
|
3VL9220-4TM31
|
ÀÊÑÅÑÑÓÀÐ ÄËß VL150UL (DG-FRAME) LUG CONNECTIONS 1 SET = 3 UNITS
|
SIEMENS
|
3VL9220-4TC31
|
ÀÊÑÅÑÑÓÀÐ ÄËß VL150UL, (DG-FRAME) ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌS COMPRISING 3 BOX TERMINALS 3-ÏÎËÞÑÀ
|
SIEMENS
|
3VL9216-8TC00
|
ÏÐÈÍÀÄËÅÆÍÎÑÒÜ ÄËß VL160 ÒÐÀÍÑÔÎÐÌÀÒÎÐ ÒÎÊÀ ÄËß ÇÀÙÈÒÛ ÎÒ ÏÅÐÅÃÐÓÇÊÈ Â N-ÏÐÎÂÎÄÍÈÊÅ È ÊÇ ÍÀ ÇÅÌËÞ IN=125A/160A
|
SIEMENS
|
3VL9216-7EM40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ ÒÅÐÌÎÌÀÃÍÈÒÍÛÉ, LI IR=125...160A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ , II= 800...1600 A,
|
SIEMENS
|
3VL9216-7EJ40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ ÒÅÐÌÎÌÀÃÍÈÒÍÛÉ, LI IR= 125...160A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ ,
|
SIEMENS
|
3VL9216-7DC30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ ÒÅÐÌÎÌÀÃÍÈÒÍÛÉ, LI IR= 125...160 A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ
|
SIEMENS
|
3VL9216-6SH30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU22, LSIG 3 ÔÀÇÍ.S/4 CABLES WITH ÑÎÅÄÈÍÈÒÅËÜÍÛÉ ÊÀÁÅËÜ IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREW TERMINAL CONNECTIONS IN SCOPE OF SUPPLY OF THE CONTACT UNIT, TRIPPING MAGNET INTEGRATED
|
SIEMENS
|
3VL9216-6TH40
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 4-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU22, LSIG IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6TF40
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 4-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6SP30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, MOTOR/GENERATOR PROT. ETU10M, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6MH30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU22, LSIG 3 ÔÀÇÍ.S/4 WIRES WITH CONNECTING LEAD IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6SG30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU22, LSIG 3 ÔÀÇÍ.S/3 WIRES IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6SL30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU12, LIG 3 ÔÀÇÍ.S/3 WIRES IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6SE30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6SB30
|
ÐÀÑÖÅÏÈÒÅËÜ VL 160 3-ÏÎËÞÑÀ, SYSTEM PROTECTION ETU10, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION ÐÀÌÎ×ÍÛÉ ÇÀÆÈÌ/SCREWED UNION CONNECTIONS IN SCOPE OF DELIÎ×. OF CONTACT UNIT
|
SIEMENS
|
3VL9216-6LS30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎË., MOTOR PROTECTION ETU30M, LI IR= 64...160A, OVERLOAD PROTECTION, TC= 10A ... 30,TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL -ÏÎË. LRS, DNV AND GL
|
SIEMENS
|
3VL9216-6LF40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎË., PLANT PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION, N-PROTECTED BOX TERMINALS/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL -ÏÎË. LRS, DNV AND GL
|
SIEMENS
|
3VL9216-6LE30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎË., PLANT PROTECTION ETU20, LSI IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL -ÏÎË. LRS, DNV AND GL
|
SIEMENS
|
3VL9216-6LB30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎË., PLANT PROTECTION ETU10, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION BOX TERMINAL/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL -ÏÎË. LRS, DNV AND GL
|
SIEMENS
|
3VL9216-6LA40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎË., PLANT PROTECTION ETU10, LI IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION, N-PROTECTED BOX TERMINALS/SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL -ÏÎË. LRS, DNV AND GL
|
SIEMENS
|
3VL9216-6CP30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎËÞÑÀ, MOTOR/GENERATOR PROT. LCD ETU40M, LI IR= 64...160 A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ , ISD=1.5 TO 10 X IR, II=11 X IN
|
SIEMENS
|
3VL9216-6CN40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ LCD ETU42, LSIG IR= 64...160 A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ ,
|
SIEMENS
|
3VL9216-6CL30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ LCD ETU42, LSIG 3ÔÀÇÛ/3ÏÐÎÂÎÄÀ IR= 64...160 A,
|
SIEMENS
|
3VL9216-6CJ40
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 4-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ LCD ETU40, LI/LS/LSI IR= 64...160 A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ ,
|
SIEMENS
|
3VL9216-6CH30
|
ÌÀÊÑ.ÐÀÑÖ. VL 160 3-ÏÎËÞÑÀ, ÇÀÙÈÌÒÀ ÑÈÑÒÅÌ LCD ETU40, LI/LS/LSI IR= 64...160 A, ÇÀÙÈÒÀ ÎÒ ÏÅÐÅÃÐÓÇÊÈ ,
|
SIEMENS
|
3VL9216-5GD40
|
ÏÐÈÍÀÄËÅÆÍÎÑÒÜ ÄËß VL160 RCD-ÌÎÄÓËÜ IN=160A UE=230…690V 4-Õ ÏÎËÞÑÍÛÉ
|
SIEMENS
|
3VL9216-5GD30
|
ÏÐÈÍÀÄËÅÆÍÎÑÒÜ ÄËß VL160 RCD-ÌÎÄÓËÜ IN=160A UE=230…690V 3-Õ ÏÎËÞÑÍÛÉ
|
SIEMENS
|
Òîâàðû
961 - 990 èç 1642
Íà÷àëî
|
Ïðåä.
|
31
32
33
34
35
|
Ñëåä. |
Êîíåö
| Âñå
|