art.1SBL351001R8000 - A50-30-00 220-230V 50Hz / 230-240V 60Hz Contactor (A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applicatio | Quad Industry GmbH
Àðòèêóë: 1SBL351001R8000
Íàèìåíîâàíèå: A50-30-00 220-230V 50Hz / 230-240V 60Hz Contactor (A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.)
Ïðîèçâîäèòåëü: ABB
Êàðòèíêè îïèñàíèÿ: 1SFC101044F0202_720.jpg, 1SFC101043F0202_720.jpg, acrosstheline.jpg, CP_Block_Contactors.jpg, 1SBC101292F0010_720.jpg, 1SFC101043F0201_720.jpg
A50-30-00 220-230V 50Hz / 230-240V 60Hz
General Information
Extended Product Type:
A50-30-00 220-230V 50Hz / 230-240V 60Hz
Product ID:
1SBL351001R8000
EAN:
3471522081803
Catalog Description:
A50-30-00 220-230V 50Hz / 230-240V 60Hz Contactor
Long Description:
A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage:
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ??C 100 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 ??C 100 A (690 V) 55 ??C 85 A (690 V) 70 ??C 70 A
Rated Operational Current AC-3 (Ie):
(1000 V) 55 ??C 23 A (220 / 230 / 240 V) 55 ??C 53 A (380 / 400 V) 55 ??C 50 A (415 V) 55 ??C 50 A (440 V) 55 ??C 45 A (500 V) 55 ??C 45 A (690 V) 55 ??C 35 A
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 100 A
Rated Short-time Withstand Current (Icw):
at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 ??C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency:
AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ?? òÉä 55 ??C) ??C
Rated Control Circuit Voltage (Uc):
50 Hz 220 òÀæ 230 V 60 Hz 230 òÀæ 240 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 18 V??A Average Holding Value 50 / 60 Hz 5.5 W Average Pull-in Value 50 Hz 190 V??A Average Pull-in Value 60 Hz 180 V??A
Operate Time:
Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Connecting Capacity Main Circuit:
Flexible with Cable End 6 ... 16 mm?? Rigid Cable 6 ... 25 mm??
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm?? Rigid Cable 1 ... 4 mm??
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting terminals (delivered in open position) Main poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal Type:
Screw Terminals
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 ??C Close to Contactor for Storage -60 ... +80 ??C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 ??C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 ??C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment