| Similar to image | | EMERG. STOP SWITCH 3-POLE IU=16, P/AC-23A AT 400V=7.5KW FRONT MOUNTING CENTER HOLE MOUNTING ROTARY ACTUATOR RED/YELLOW (EMERG. STOP) |
|
General technical details: |
Product brand name | | SENTRON |
product designation | | main and EMERGENCY-OFF switches |
Type from device | | fixed mounting |
Design of the operating mechanism | | rotary actuator, red/yellow |
Protection class IP | | IP65 |
Number of poles | | 3 |
Acceptability for application | | |
| | Yes |
| | Yes |
| | Yes |
| | Yes |
- maintenance/repair switch
| | Yes |
Product equipment / interlock | | Yes |
Type of the driving mechanism / motor drive | | No |
Product extension / optional | | |
| | No |
| | No |
Ambient temperature / during operating | °C | -25… +55 |
Insulation voltage / rated value | V | 690 |
Impulse voltage resistance / rated value | V | 6,000 |
Active power loss / per conductor / typical | W | 0.5 |
Mechanical operating cycles as operating time / of the main contacts / typical | | 100,000 |
Protection against electrical shock | | finger-safe |
Item designation / according to DIN EN 61346-2 | | S |
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 | | S |
|
Main circuit: | | |
Continuous current / rated value | A | 16 |
Operating current / at AC-21 / rated value | A | 16 |
Short-time current resistance (Icw) / at 690 V / limited to 1 s / rated value | A | 340 |
Operating frequency | Hz | 50… 60 |
Operating voltage / at 50/60 Hz / for AC / rated value | V | 690 |
Service power / at AC-3 | | |
| kW | 5.5 |
| kW | 5.5 |
Service power / at AC-23 A | | |
| kW | 7.5 |
| kW | 7.5 |
Operating cycles / maximum | 1/h | 50 |
|
Auxiliary circuit: | | |
Number of NC contacts / for auxiliary contacts | | 0 |
Number of NO contacts / for auxiliary contacts | | 0 |
Number of change-over switches / for auxiliary contacts | | 0 |
Continuous current / of the auxiliary contact / rated value | A | 10 |
Operating voltage / of the auxiliary contacts / for AC / maximum | V | 500 |
Insulation voltage / of the auxiliary switch / rated value | V | 500 |
|
Short-circuit: | | |
Design of the fuse link / for short-circuit protection of the main circuit / necessary | | fuse gL/gG: 20 A |
Design of the fuse link / for short-circuit protection of the auxiliary switch / required | | fuse gL/gG: 10 A |
|
Installation/mounting/dimensions: | | |
Type of mounting | | front mounting |
| | Yes |
- front mounting with central fixation
| | Yes |
- front mounting with 4-hole fixation
| | No |
| | Yes |
| | No |
Width | mm | 67 |
Height | mm | 84 |
Depth | mm | 116.5 |
|
Connection type: |
Design of the electrical connection / for main current circuit | | connection terminals |
Design of the electrical connection / for auxiliary contact | | connection terminals |
Type of the connectable conductor cross-section / for main contacts | | |
| | 1 ... 6 mm2 |
- finely stranded / with conductor end processing
| | 4 mm? |
| | 1 ... 6 mm2 |
Type of connectable conductor cross section / for auxiliary contacts | | |
| | 2x (0.75 to 2.5 mm2), 1x 4 mm2 |
| | 2x (0.75 ... 2.5 mm2), 1x 4 mm2 |
|
Certificates/approvals: |
Verification of suitability | | CSA / UL / CCC / GL / LRS / DNV / PRS |
Conductor cross section that can be connected / for main contacts / solid / minimum | mm? | 1 |
Conductor cross section that can be connected / for main contacts / solid / maximum | mm? | 6 |
Conductor cross section that can be connected / for main contacts / stranded / minimum | mm? | 1 |
Conductor cross section that can be connected / for main contacts / stranded / maximum | mm? | 6 |
Conductor cross-section that can be connected / for main contacts / stranded wire / with conductor end processing / maximum | mm? | 4 |
Conductor cross section that can be connected / for auxiliary contacts / solid / minimum | mm? | 0.75 |
Conductor cross section that can be connected / for auxiliary contacts / solid / maximum | mm? | 4 |
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / minimum | mm? | 0.75 |
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / maximum | mm? | 2.5 |
Conductor cross section that can be connected / for auxiliary contacts / stranded / min. | mm? | 0.75 |
Conductor cross section that can be connected / for auxiliary contacts / stranded / max. | mm? | 4 |
|
Certificates/approvals: |
General Product Approval | Test Certificates | | |
|
|
last change: | Dec 12, 2011 |