AWM1100V - Airflow Sensor, Signal Conditioning: Unamplified (mV), Flow/Pressure Range: ±200 sccm, Port Style: Straight || AWM1100V - Quad Industry GmbH
Àðòèêóë: AWM1100V
Íàèìåíîâàíèå: Airflow Sensor, Signal Conditioning: Unamplified (mV), Flow/Pressure Range: ±200 sccm, Port Style: Straight || AWM1100V
Ïðîèçâîäèòåëü: Honeywell
|
|

Description | Take advantage of microbridge mass flow sensor technology. The AWM1000 series mass flow sensor provides all of the outstanding performance benefits of the standard AWM2000 series in a more cost-effective sensor platform. This device provides accurate, repeatable flow sensing. Sensor to sensor interchangeability specifications are approximately twice as large as compared to the AWM2000 series. The heater control circuit and the sensing bridge supply circuit are both required for operation per specification. These two circuits are not on board the sensor and must be supplied in the application. The differential amplifier circuitry may be useful in providing output gain and/or introducing voltage offsets to the sensor output. | CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage. | Features | - Cost-effective microbridge technology
- Accurate, repeatable airflow sensing
- Bi-directional sensing capability
- Low differential pressure sensing
| | Typical Applications | - Damper control for heating, ventilation, and air conditioning systems
- Gas analyzers
- Low vacuum control
- Process control
- Medical respirators and ventilators
- Oxygen concentrators
- Leak detection equipment
- Vent hoods
- Anesthesia control
- Gas metering
- Gas chromatography
| | Product Specifications | Signal Conditioning | Unamplified (mV) | Flow/Pressure Range | ±200 sccm | Output Voltage at Trim Point | 30.0 mV dc @ 100 sccm | Port Style | Straight | Series Name | AWM1000 | Null Shift over Temperature | ±0.7 mV dc max. | Output Shift over Temperature | ±4 % Full Scale | Flow Rate Change | 5.0 SLPM/s | Repeatability | ±1 % Full Scale | Null Offset | ±1 mV dc | Response Time | 1 ms typ., 3 ms max. | Supply Voltage | 8.0 Vdc min., 10.0 Vdc typ., 15.0 Vdc max. | Common Mode Pressure | 25 psi | Power Consumption | 30 mW typ., 50 mW max. | Operating Temperature | -25 °C to 85 °C [-13 °F to 185 °F] | Storage Temperature | -40 °C to 90 °C [-40 °F to 194 °F] | Media Compatibility | Dry gas only | Sensor Resistance | 5.0 kOhm | Sensor Current | 0.3 mA typ., 0.6 mA max. | Weight | 10.8 g | Shock | 100 g peak (5 drops, 6 axes) | Availability | Global | UNSPSC Code | 41111931 | UNSPSC Commodity | 41111931 Flow Sensors |
|