RSD-GW2-Ex1.PA.ED - PROFIBUS PA gateway HART | RSD-GW2-Ex1.PA.ED - Quad Industry GmbH
Артикул: RSD-GW2-Ex1.PA.ED
Наименование: PROFIBUS PA gateway HART | RSD-GW2-Ex1.PA.ED
Производитель: Pepperl-Fuchs
Not available for purchase, If you need assistance please contact us sales@quad-industry.com Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@quad-industry.com
Connects the IS-RPI system to the control system via PROFIBUS PA Fieldbus intrinsically safe EEx ia IIC Device installation in Zone 1, Zone 2, or Zone 22 Up to 6 gateways on one intrinsically safe bus network Transfer rate 31.25 kBits/s Up to 8 I/O modules on one gateway via the backplane bus PROFIBUS PA with intrinsically safe IEC 61158-2 transmission technology PROFIBUS PA interface in accordance with FISCO Transfer of HART signals LED status indication Channel specific PROFIBUS diagnosis Gateway can be replaced under voltage in zone 1 (hot swap) EMC acc. to NAMUR NE 21
Datasheet as PDF in following languages:
Technical Data: RSD-GW2-Ex1.PA.ED Supply Connection terminals V+, V- Rated voltage 8.88 ... 9.5 V Power loss 3.5 W Power consumption 4.25 W Internal bus Connection backplane bus Interface manufacturer specific bus Cycle time 1.6 ms External bus Connection terminals 1-, 2+ Rated voltage min. 9 V Rated current max. 13.2 mA FDE (Fault Disconnect Equipment) max. 9 mA Interface PROFIBUS PA with intrinsically safe IEC 61158-2 transfer technique Transfer rate 31.25 kBit/s Bus address 1 ... 99 , adjustable via switch Directive conformity Electromagnetic compatibility Directive 89/336/EEC EN 61326 Explosion protection Directive 94/9/EC EN 50014, EN 50020, EN 50284, EN 50281-1-1 Standard conformity Insulation coordination EN 50178 Electrical isolation EN 50020 Electromagnetic compatibility NE 21 Protection degree IEC 60529 Climatic conditions IEC 60721 Ambient conditions Classification 3K3 Ambient temperature -20 ... 70 °C (-4 ... 158 °F) Storage temperature -20 ... 100 °C (-4 ... 212 °F) Relative humidity 95 % non-condensing Shock resistance 15 g peak, 11 ms period Vibration resistance 2 g , 10 ... 500 Hz according to IEC 60068-2-6 Damaging gas acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type Terminals Core cross-section max. 2.5 mm2 Protection degree IP20, for on-site installation a separate housing is required with a minimum of IP54 Mass approx. 305 g Mounting DIN rail mounting Data for application in connection with Ex-areas EC-Type Examination Certificate DMT 99 ATEX E 001 X , for additional certificates see www.pepperl-fuchs.com Group, category, type of protection II (1)2G EEx ia/ib IIC II (1D)(2D)Temperature class T4 Supply only in connection with the power units RSD2-PSD2-Ex4.34, RSA6-PSD-Ex4.34 External bus Voltage 15.75 V Current 250 mA Power 1.93 W Internal capacitance 120 pF Internal inductance negligible Internal bus customer specific Statement of conformity Group, category, type of protection, temperature class II 3D IP54 T 90°CElectrical isolation Internal/external bus no electrical isolation Internal bus/power supply safe galvanic isolation acc. to EN 50020, voltage peak value 60 V External bus/power supply safe galvanic isolation acc. to EN 50020, voltage peak value 60 V
Назад в раздел