Connects the IS-RPI system with the control system via PROFIBUS DP Fieldbus intrinsically safe EEx ib IIC Device installation in Zone 1, Zone 2, or Zone 22 Up to 10 gateways on one intrinsically safe bus network PROFIBUS DP V1 up to 1.5 MBit/s Up to 8 I/O modules on one gateway via the backplane bus PROFIBUS DP media redundancy Transfer of HART signals LED status indication Channel specific PROFIBUS diagnosis Gateway can be replaced under voltage in zone 1 (hot swap) EMC acc. to NAMUR NE 21
Datasheet as PDF in following languages:
Technical Data: RSD-GW3-Ex2.DPE.ED Supply Connection terminals V+, V- Power loss 8 W Power consumption 8.5 W Internal bus Connection backplane bus Interface manufacturer specific bus Cycle time 1.6 ms External bus Connection terminals 1+, 2- Interface PROFIBUS with intrinsically safe RS 485 transfer technique Transfer rate 9.6 ... 1500 kBit/s Bus address 1 ... 99 , adjustable via switch Terminating impedance adjustable with sliding switch: I = OFF; ON = ON Directive conformity Electromagnetic compatibility Directive 89/336/EEC EN 61326 Explosion protection Directive 94/9/EC EN 50014, EN 50020, EN 50281-1-1 Standard conformity Insulation coordination EN 50178 Electrical isolation EN 50020 Electromagnetic compatibility NE 21 Protection degree IEC 60529 Climatic conditions IEC 60721 Ambient conditions Classification 3K3 Ambient temperature -20 ... 70 °C (-4 ... 158 °F) Storage temperature -20 ... 100 °C (-4 ... 212 °F) Relative humidity 95 % non-condensing Shock resistance 15 g peak, 11 ms period Vibration resistance 2 g , 10 ... 500 Hz according to IEC 60068-2-6 Damaging gas acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type Terminals Core cross-section max. 2.5 mm2 Protection degree IP20, for on-site installation a separate housing is required with a minimum of IP54 Mass approx. 325 g Mounting DIN rail mounting Data for application in connection with Ex-areas EC-Type Examination Certificate DMT 00 ATEX 023 X , for additional certificates see www.pepperl-fuchs.com Group, category, type of protection II 2G EEx ib IIC II (2D)Temperature class T4 Supply only in connection with the power units RSD2-PSD2-Ex4.34, RSA6-PSD-Ex4.34 External bus Voltage ± 3.72 V Current 76.5 mA Power 103 mW Voltage ± 3.75 V Internal capacitance negligible Internal inductance negligible External capacitance 100 µF External inductance 1.5 mH L/R-ratio 344 µH/Ω Internal bus customer specific Statement of conformity Group, category, type of protection, temperature class II 3D IP54 T 90°CElectrical isolation Internal/external bus no electrical isolation Internal bus/power supply safe galvanic isolation acc. to EN 50020, voltage peak value 60 V External bus/power supply safe galvanic isolation acc. to EN 50020, voltage peak value 60 V
Назад в раздел